Single Phase 2.5KW 3KW 4.2KW 4.6KW 5Kva 6KW MPPT Solar Inverter for Grid Tied Solar Power System.

Single Phase 2.5KW 3KW 4.2KW 4.6KW 5Kva 6KW MPPT Solar Inverter for Grid Tied Solar Power System.
  • Output Type:
    Single Phase
  • Model:
    MIN 5000TL-X
  • Output Power:
    2.5-6 KW
  • Input Voltage:
    80-500V DC
  • Output Voltage:
    230V(160V-300V)
  • Output Frequency:
    50Hz/60Hz

Maximum efficiency 98.4%,Dual MPP trackers, Type II SPD on DC side, Supports export control, Supports export control.

description

Single Phase 2.5KW 3KW 4.2KW 4.6KW 5Kva 6KW MPPT Solar Inverter for Grid Tied Solar Power System.

 

Features:
• Maximum efficiency 98.4%.
• Solar Inverter with Dual MPP trackers
• Type II SPD on DC side
• Solar Inverter supports export control
• Touch key and OLED display
• Easy installation.

 DATASHEETMIN2500TL-XMIN3000TL-XMIN4200TL-XMIN5000TL-XMIN6000TL-X
 Input Data (DC)
 Max. PV Power (at STC)3500W4200W5880W7000W8100W
 Max. DC Voltage500V500V550V550V550V
 Start Voltage100V100V100V100V100V
 MPP Voltage Range     80V-500V80V-500V80V-550V80V-550V80V-550V
 Nominal Voltage 360V360V360V360V360V
 Max. Input Current12.5A/12.5A12.5A/12.5A12.5A/12.5A12.5A/12.5A12.5A/12.5A
 Max. Short-Circuit Current 16A/16A16A/16A16A/16A16A/16A16A/16A
 Number. of Independent MPP Trackers/strings per MPP tracker2/12/12/12/12/1
 Output Data (AC)
 Rated AC Output Power2500W3000W4200W5000W6000W
 Max. AC Apparent Power2500VA3000VA4200VA5000VA6000VA
 Max. Output Current11.3A13.6A16A19A20.9A
 AC Nominal Voltage230V(160V-300V)
 AC Grid Frequency50Hz/60Hz,±5Hz
 Adjustable Power Factor0.8leading… 0.8lagging
 THDI<3%
 AC connectionSingle Phase
 Efficiency
 Max. Efficiency98.2%98.2%98.4%98.4%98.4%
 Euro Weighted Efficiency97.1%97.1%97.5%97.5%97.5%
 MPPT Efficiency99.9%99.9%99.9%99.9%99.9%
 Protection Devices
 DC Reverse Polarity Protectionyesyesyesyesyes
 DC Switch yesyesyesyesyes
 DC Surge Protection Type IIType IIType IIType IIType II
 Output Over Current Protectionyesyesyesyesyes
 Over Voltage.Protection Varistoryesyesyesyesyes
 Ground Fault Monitoringyesyesyesyesyes
 Grid Monitoringyesyesyesyesyes
 Integrated all – pole sensitive  leakage current monitoring unityesyesyesyesyes
 General Data
 Dimensions (W*H*D) MM375*350*160375*350*160375*350*160375*350*160375*350*160
 Weight (KG)10.810.810.810.810.8
 Operating Temp.Range–25°C ∼+60°C with derating above 45°C
 Noise Emission(Typical)≤25 dB(A)
 Altitude4000m 
 Self-Consumption Night<0.5 W
 TopologyTransformerless
 Cooling ConceptNatural
 Environmental Protection RatingIP 65
 Relative Humidity100%
 Features
 DC ConnectionH4/MC4(opt)
 AC connectionConnector
 DisplayOLED+LCD
 Interface: RS485/ USB/ WiFi/4G/RFyes /yes/opt/opt/opt
 Warranty: 5 years / 10 yearsyes /opt
 Certificates and ApprovalsCE, IEC62109, G83, VDE0126-1-1, VFR2014, G59, AS4777, AS/NZS 3100, CEI0-21, VDE-AR-N4105, EN50438, CQC, IEC61683, IEC60068, IEC61727, IEC62116
Related Products Tags:

send us your Single Phase 2.5KW 3KW 4.2KW 4.6KW 5Kva 6KW MPPT Solar Inverter for Grid Tied Solar Power System.

verification image contact form FAQ